Pyrotec A50 Animal Incinerator

Techtol Pyrotec AP150 Animal Incinerator

A50 - Animal Incinerator

The Pyrotec A50 is a modern incinerator designed to burn animal carcass waste in an efficient, clean and environmentally safe manner. Using the Pyrolytic principle of combustion, it is particularly suited for small animal carcasses. This model is specifically for burning domestic pets and animal remains and is equipped with the necessary sophistication of control, secondary chamber volume, manual loading and chimney.

Description
  Models:    A50
  Waste type:    Animal Carcass waste – calorific value 1,000 kcal/kg, density 700 kg/m³, moisture content 85%.
  Construction:    Mild steel fabrication construction using 5mm steel plate suitability braced and stiffened..
  Refractory:   Primary Chamber: Hot face material 1,600°C quality 100mm thick, backed by 25mm  ceramic fibre insulation.
  Secondary Chamber: Hot face material 1,500ºC quality.
  Fuel:   Natural gas, LP gas or 35 seconds fuel oil.
  Electrical supply:   380/440 volt, 3 phase, 50/60hz, 230 volt, 1 phase, 50/60hz
  Burners:   Automatic package burners complete with electric ignition and flame failure control complete with all necessary valves, motors and integral continuous running fan.   Automatically temperature controlled to provide optimum combustion conditions, primary and secondary chamber temperatures and fuel economy.
  Primary Chamber: one at 185,000 kcal/hr on/off control
  Secondary Chamber: one at 185,000 kcal/hr on/off control
  Fans   No fans required. All combustion and cooling air is provided by ambient air through strategically located air nozzles throughout the combstion chambers to ensure optimum conditions.
  Finish   One coat of primer followed by one coat of enamel finish in red.
 Control panel

  Automatic control system built to IEC standards incorporating relay control, providing all automatic plant functions and incorporating the following sequences.

  1) Preheat cycle

  2) Burn cycle

  3) Cool down cycle

  Monitors   The standard control system provides a digital display of the secondary chamber temperatures; however, in some instances the local DEFRA official may require the temperature to be permanently recorded by a dedicated chart recorder.

  Loading/ash removal door

  A full size manually operated access door for waste loading/deashing.