Techtrol Limited

pyrotec A50 plus animal cremator

design
The Pyrotec A50 Plus is a modern incinerator designed to burn animal carcass waste in an efficient clean and environmentally safe manner using the Pyrolytic principle of combustion, it is particularly suited for small animal carcasses this model is specifically for burning domestic pets and animal remains and is equipped with the necessary sophistication of control, secondary chamber volume, manual loading and chimney.

model
A50 plus

standard
EU Animal by Product Regulation EC1774/2002
UK Animal by Product Regulation 2005
DEFRA Type Approved
Secondary Chamber Residence time: - 2.0 seconds at 850°C

waste type
Animal Carcass waste calorific value 1,000 kcal/kg, density 700 kg/m³, moisture content 85%.

construction
Mild steel fabrication construction using 5mm steel plate suitability braced and stiffened.

refractory
Primary Chamber
Hot face material 1,600°C quality 100mm thick, backed by 25mm ceramic fibre insulation.

Secondary Chamber
Hot face material 1,500°C quality complete with 65% alumina tiles.

fuel
Natural gas, LP gas or 35 seconds fuel oil.

electrical supply
380/440 volt, 3 phase, 50/60hz
230 volt, 1 phase, 50/60hz

burners
Automatic package burners complete with electric ignition and flame failure control complete with all the necessary values. Motors and integral fan continuous running fan. Automatically temperature controlled to provide optimum combustion conditions, secondary chamber temperatures and fuel economy.

Primary Chamber one at 185,000 kcal/hr on/off control
Secondary Chamber one at 185,000 kcal/hr on/off control

fan
All combustion and cooling air is provided by a common automatically controlled centrifugal fan, which provides air to nozzles strategically, located throughout the combustion chambers to ensure optimum conditions.

finish
One coat of primer followed by one coat of enamel finish in red.

control panel
Automatic control system built to IEC standards incorporating relay control, providing all automatic plant functions and incorporating the following sequences.

1) Preheat
2) Burn cycle
3) Cool down

monitors
The standard control system provides a digital display of the secondary chamber temperature; however, in some instances the local DEFRA official may require the temperature to be permanently recorded by a dedicated chart recorder.

loading/ash removal door
A full size manually operated access door for waste loading/deashing.

Animal A50plus cremator Animal A50plus cremator

Pyrotec model

A50 plus

Capacity:

Kg/hr

50

Thermal KCal/hr

50,000

Dimensions (m):

A

2.10

B

1.20

C

1.30

D

2.20

E

5.00

Chimney internal diameter (m)

0.30

Manual loading door size (m)

1.00

Primary chamber volume (m³)

0.80

Secondary chamber volume (m³)

0.33

Note :-
Burning capacities are based on waste having a calorific value of 1,000 KCal/Kg.
Our specifications are subject to alteration due to our continuous product improvement policy.