Techtrol Limited

pyrotec A50L animal cremator

design
The Pyrotec A50L range of incinerators is designed to burn animal remains and carcase material in an efficient, clean and environmentally safe manner. The range was initially developed and designed to meet the stringent standards of the EU Animal By-Product Regulations EC1774/2002, where these related to low capacity incinerators. However we have now extended the range by the addition of two enhanced versions that may be utilised within non-EU countries. These versions are built to the same exacting standards but have higher burner ratings and so offer increased throughput capacities. The two units are specifically designed for the destruction of animal remains and carcases derived from farms, abattoirs and other such establishments.
Animal A50(L) cremator Animal A50(L) cremator

models
A50L(3), A50L(4)

waste types
Animal Remains and Carcases

construction
Fabricated mild steel construction using 5mm steel plate suitability braced and stiffened.

refractory
Primary Chamber
Hot face material 1,600°C quality 115mm thick, backed by 38mm calcium silicate insulation.

Secondary Chamber
Hot face material 1,550°C quality 80mm thick backed by 38mm ceramic fibre insulation.

fuel
Natural gas or diesel fuel oil.

electrical supply
380/440 volt, 3 phase, 4 wire, 50hz

burners
Each unit is fitted with automatic package burners, which are complete with electric ignition and flame failure control devices and all necessary valves, motors and integral continuous running fan. They are automatically temperature controlled to provide optimum combustion conditions, adequate secondary chamber temperatures and fuel economy.

Primary Chamber three or four burners rated at 200kW with on/off control
Secondary Chamber one burner rated at 400kW with high/low control

fans
All combustion and cooling air is provided by automatically controlled (automatic loading) centrifugal fans, which provide air to nozzles strategically located throughout the combustion chambers to ensure optimum conditions.

loading door
Pneumatic powered automatic top loading door designed to operate in unison with the incinerator operation having programmable time and temperature operating sequence to ensure maximum throughput. Complete with waste feed hopper to accept pallet or boxed waste for loading with bin tipper or forklift truck.

finish
Two coats of primer followed by two coats of enamel finish in red.

control panel
Automatic control system built to IEC standards incorporating relay control, providing all automatic plant functions and incorporating the following sequences.

1) Preheat
2) Burn cycle
3) Burndown
4) Cooldown

The control panel will be equipped with an active mimic diagram showing operating status of the plant together with indication of primary, secondary chambers and exhaust temperatures.
Animal A50L cremator Animal A50L cremator

Pyrotec model

A50L(3)

A50L(4)

Nominal loading capacity:

Kg/hr

450

550

Nominal throughput capacity:

Kg/hr

125

125

Thermal capacity:

MJ/hr

375

375

Dimensions (m):

A

2.50

2.50

B

3.50

4.00

C

1.50

1.50

D

1.70

1.70

E

3.70

3.70

F

8.00

8.00

Chimney internal diameter (m)

0.54

0.54

Access door opening diameter (m)

1.40

1.40

Note :-
Burning capacities are based on waste having a calorific value of 1,000 KCal/Kg.
Our specifications are subject to alteration due to our
continuous product improvement policy.